Control Cable (CVV, CVV-S, CVV-SWA)

CVV 0.6/1KV Control Cable

Conductor: Concentric Stranded copper wire
Cores: 2-30 core
Insulation: PVC Black color
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Sheath: PVC Black color
Application: For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.

sales@huadongcable.ph

4 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
40.57/0.300.81.811360.0162130500/D
0.757/0.370.81.811.524.50.0142150500/D
17/0.400.81.811.518.10.0135160500/D
1.57/0.500.81.812.512.10.0115195500/D
2.57/0.670.81.8147.410.0093265500/D
47/0.8511.816.54.610.0092390500/D
67/1.0411.8173.080.0078510500/D

sales@huadongcable.ph

5 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
50.57/0.300.81.811.5360.0162150500/D
0.757/0.370.81.812.524.50.0142175500/D
17/0.400.81.812.518.10.0135190500/D
1.57/0.500.81.813.512.10.0115230500/D
2.57/0.670.81.8157.410.0093320500/D
47/0.8511.8184.610.0092470500/D
67/1.0411.819.53.080.0078620500/D

sales@huadongcable.ph

6 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
60.57/0.300.81.812.5360.0162165500/D
0.757/0.370.81.81324.50.0142190500/D
17/0.400.81.813.518.10.0135205500/D
1.57/0.500.81.814.512.10.0115255500/D
2.57/0.670.81.8167.410.0093355500/D
47/0.8511.819.54.610.0092525500/D
67/1.0411.8213.080.0078690500/D

sales@huadongcable.ph

7 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
70.57/0.300.81.812.5360.0162170500/D
0.757/0.370.81.81324.50.0142200500/D
17/0.400.81.813.518.10.0135215500/D
1.57/0.500.81.814.512.10.0115270500/D
2.57/0.670.81.8167.410.0093380500/D
47/0.8511.819.54.610.0092570500/D
67/1.0411.8213.080.0078795500/D

sales@huadongcable.ph

8 Core CVV 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmOhm/kmOhm/kmkg/kmm
80.57/0.300.81.813.5360.0162195500/D
0.757/0.370.81.81424.50.0142230500/D
17/0.400.81.814.518.10.0135250500/D
1.57/0.500.81.815.512.10.0115310500/D
2.57/0.670.81.817.57.410.0093440500/D
47/0.8511.8214.610.0092660500/D
67/1.0411.8233.080.0078875500/D

sales@huadongcable.ph

CVV-S 0.6/1KV Control Cable 60502 Standard

Conductor: Concentric Stranded copper wire
Core: 2-15 cores
Insulation: PVC Black color
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Inner sheath: PVC Black color
Shield: Annealed copper tape
Binding tape: Suitable tape
Outer Sheath: PVC Black color
Application: For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.

sales@huadongcable.ph

4 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
40.57/0.300.811.813.5360.0162220500/D
0.757/0.370.811.81424.50.0142245500/D
17/0.400.811.814.518.10.0135260500/D
1.57/0.500.811.815.512.10.0115300500/D
2.57/0.670.811.816.57.410.0093385500/D
47/0.85111.8194.610.0092530500/D
67/1.04111.820.53.080.0078660500/D

sales@huadongcable.ph

5 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
50.57/0.300.811.814.5360.0162250500/D
0.757/0.370.811.81524.50.0142280500/D
17/0.400.811.815.518.10.0135295500/D
1.57/0.500.811.816.512.10.0115345500/D
2.57/0.670.811.8187.410.0093445500/D
47/0.85111.820.54.610.0092620500/D
67/1.04111.822.53.080.0078780500/D

sales@huadongcable.ph

6 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
60.57/0.300.811.815.5360.0162270500/D
0.757/0.370.811.81624.50.0142305500/D
17/0.400.811.816.518.10.0135320500/D
1.57/0.500.811.817.512.10.0115375500/D
2.57/0.670.811.8197.410.0093290500/D
47/0.85111.8224.610.0092685500/D
67/1.04111.8243.080.0078865500/D

sales@huadongcable.ph

7 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
70.57/0.300.811.815.5360.0162275500/D
0.757/0.370.811.81624.50.0142315500/D
17/0.400.811.816.518.10.0135330500/D
1.57/0.500.811.817.512.10.0115395500/D
2.57/0.670.811.8197.410.0093520500/D
47/0.85111.8224.610.0092730500/D
67/1.04111.8243.080.0078930500/D

sales@huadongcable.ph

8 Core CVV-S 0.6/1KV Control Cable Technical Parameter------Learn More...
No. of coreNominal cross-sectional areaNo.& dia.ThicknessThickness of inner sheathThicknessOverall diameter (Approx.)Maximum conductor resistanceMinimum insulation resistanceCableStandard Length
of wires of insulation of outer sheath(at20C)(at70C)weight (Approx.)
mm2No./mmmmmmmmmmOhm/kmOhm/kmkg/kmm
80.57/0.300.811.816360.0162310500/D
0.757/0.370.811.81724.50.0142350500/D
17/0.400.811.81718.10.0135370500/D
1.57/0.500.811.818.512.10.0115445500/D
2.57/0.670.811.8207.410.0093590500/D
47/0.85111.823.54.610.0092835500/D
67/1.04111.825.53.080.00781070500/D

sales@huadongcable.ph

CVV-SWA 0.6/1KV Control Cable

Conductor: Concentric Stranded annealed copper wire
Insulation: PVC Black color
Core: 2-30 Core
Identification: Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Inner sheath: PVC Black color
Armour: Galvanized steel wire
Binding tape: Suitable tape
Outer Sheath: PVC Black color
Application: For use in duct, tray and for direct burying in ground. The cable subjects to immerse in water all the line.

sales@huadongcable.ph

4 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
40.57/0.300.81.20.81.816.5360.0162380500/D
0.757/0.370.81.20.81.81724.50.0142410500/D
17/0.400.81.20.81.81718.10.0135425500/D
1.57/0.500.81.20.81.81812.10.0115480500/D
2.57/0.670.81.21.251.820.57.410.0093715500/D
47/0.8511.21.251.8234.610.0092915500/D
67/1.0411.21.251.824.53.080.00781075500/D

sales@huadongcable.ph

5 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
50.57/0.300.81.20.81.817360.0162420500/D
0.757/0.370.81.20.81.81824.50.0142455500/D
17/0.400.81.21.251.81918.10.0135595500/D
1.57/0.500.81.21.251.82012.10.0115665500/D
2.57/0.670.81.21.251.821.57.410.0093805500/D
47/0.8511.21.251.824.54.610.00921040500/D
67/1.0411.21.61.8273.080.00781385500/D

sales@huadongcable.ph

6 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
60.57/0.300.81.20.81.818360.0162450500/D
0.757/0.370.81.21.251.819.524.50.0142610500/D
17/0.400.81.21.251.82018.10.0135635500/D
1.57/0.500.81.21.251.82112.10.0115715500/D
2.57/0.670.81.21.251.822.57.410.0093870500/D
47/0.8511.21.61.826.54.610.00921270500/D
67/1.0411.21.61.828.53.080.00781515500/D

sales@huadongcable.ph

7 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
70.57/0.300.81.20.81.818360.0162455500/D
0.757/0.370.81.21.251.819.524.50.0142620500/D
17/0.400.81.21.251.82018.10.0135650500/D
1.57/0.500.81.21.251.82112.10.0115730500/D
2.57/0.670.81.21.251.822.57.410.0093895500/D
47/0.8511.21.61.826.54.610.00921315500/D
67/1.0411.21.61.828.53.080.00781580500/D

sales@huadongcable.ph

8 Core CVV-SWA 0.6/1KV Control Cable Technical Parameter------Learn More...
No.of core Nominal cross-sectional area No.&dia.of wires Thickness of insulation Thickness of inner sheath Diameter of steel wire armourThickness of outer sheath Overall diameter (Approx.) Maximum conductor (at20C) Minimum insulation resistance (at70C)Cable weight (Approx.) Standard Length
mm2No./mmmmmmmmmmmmOhm/kmOhm/kmkg/kmm
80.57/0.300.81.21.251.820360.0162625500/D
0.757/0.370.81.21.251.820.524.50.0142680500/D
17/0.400.81.21.251.82118.10.0135710500/D
1.57/0.500.81.21.251.82212.10.0115810500/D
2.57/0.670.81.21.251.8247.410.0093995500/D
47/0.8511.21.61.8284.610.00921470500/D
67/1.0411.21.61.8303.080.00781770500/D

sales@huadongcable.ph

Leave Message

Let's together work as for your project by E-mail: sales@huadongcable.ph

* Your Name

* Your Email

Your Phone Number

* Your Requirement